Electric Power 10KV Medium Voltage Cable XLPE Insulated Underground Power Cable


Electric Power 10KV Medium Voltage Cable XLPE Insulated Underground Power Cable  

Standard:
IEC60502, BS6346, VDE, AS/NZS, UL,etc

The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

Number of cores:

1,  3, 

Construction:

Conductor: Solid or stranded copper/aluminum
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC) 
Filler: Polypropylene filament with lapped binding tape 
Binder: Binding tape 
Inner sheath: Polyvinyl chloride (PVC) 
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA) 
Sheath: Polyvinyl chloride (PVC) 

Sectional Area: 
25 mm2  , 35 mm, 50 mm2  ,70 mm2  , 95 mm2  ,120 mm2  ,150 mm,185 mm2  ,240 mm,300 mm2  400 mm2 500 mm2 630 mm2 800 mm

 
 
TypeNameMain Application
Cu coreAl core
YJV 
YJY
YJLV 
YJLV
XLPE insulated, PVC or PE Sheathed Power CableFor laying indoor, tunnel, channel and underground. Unable to bear external mechanical force, but bear the traction force during laid
YJV22
YJV22
YJLV22
YJV22
XLPE Insulated, Steel Tape Armored, PVC or PE Sheathed Power CableFor laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force
YJV32
YJV32
YJLV32
YJLV32
XLPE Insulated, Fine Steel Wire Armored, PVC or PE Sheathed Power CableFor laying in shaft with large difference of level. Able to bear external mechanical force and moderate pulling force
YJV42YJV42YJLV42YJLV42XLPE Insulated, Thick Steel Wire Armored, PVC or PE Sheathed Power CableAble to bear positive pressure and pulling force
Note: "ZR-" includes ABC three kinds of flame retardent cables, which are respectively indicated in "ZRA-" or "ZRB-" "ZRC-". For example: "ZRB-YJV", "ZRA-YJV22".
Rated Voltage, No. of Core and Range of Sectional Area

Rated voltage (kv) 
Sectional area (mm2)
No. of core
1st class0.6/11.8/33.6/66/108.7/1512/2018/3021/35
2nd class1/13/36/68.7/1012/1518/20-26/35
1 Core 1.5-80025-80025-120025-120035-120050-120050-120050-1200
3 Core 1.5-40025-40025-40025-40035-40050-40050-40050-400

Main Technical Quota
DC resistance: conductor resistance of finished cable at 20℃ per kilometer is not more than the following values.
Nominal section area (mm2)1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221
Aluminum core18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367