11kv 3 core 95mm2 CU/PVC/SWA/PVC power cable
11kv 3 core 95mm2 CU/PVC/SWA/PVC power cable
Applications of Medium Voltage Cable
Used for power transmission and distribution line with voltage rated at 35kV and below.
Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
Standards of Medium Voltage Cable
International: IEC 60502-2, IEC 60228
China: GB/T 12706.2-2008
Other standards such as BS,DIN and ICEA upon request
| Rated Voltage: | 6/10kV, 6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV |
| Core Number: | Single Core or Three Core (1C or 3C) |
| Available Dimensions: | 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2. |
| Codes Available: | N2XSY, N2XSEY, NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY, N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY |
| YJV, YJLV, YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32 | |
| Application: | For power networks, underground, outdoors and in cable ducting. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected during installation. |
| Construction: | |
| Conductor: | Stranded round compacted copper or aluminum conductor (Cu / Al ), copper wire annealed. |
| Conductor Screen: | Semi-conducting material |
| Insulation: | XLPE (Cross-Linked Polyethylene) |
| Insulation Screen: | Semi-conducting material |
| Metallic Screen: | Copper tape screen or copper wire screen (CTS / CWS ) |
| Filler: | PP rope |
| Separator: | Binding tape |
| Bedding: | PVC (Polyvinyl Chloride) |
| Armouring: | Single Core: Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA) |
| Sheath: | PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR |
| Colour: | Red or Black |
| Temperature Rating: | 0°C to 90°C |
| Minimum Bending Radius: | Single Core: 15 x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former) |
Rated voltage(KV)
|
3.6/6
|
6/6
|
6/10
|
8.7/10
|
8.7/15
|
12/15
|
12/20
|
18/20
|
18/30
|
21/35
|
26/35
| |
Core Number
|
1 core, 3 core
| |||||||||||
Cross-section
mm2
|
1C
|
25~800
|
35~800
| |||||||||
3C
|
25~400
|
35~400
| ||||||||||
b) IEC/BS/DIN standard
Rated voltage(KV)
|
3.6/6
|
6/6
|
6/10
|
8.7/10
|
8.7/15
|
12/15
|
12/20
|
18/20
|
18/30
|
21/35
|
26/35
| |
Core Number
|
1 core, 3 core
| |||||||||||
Cross-section
mm2
|
1C
|
25~800
|
35~800
| |||||||||
3C
|
25~400
|
35~400
| ||||||||||
c) ASTM standard
Rated voltage(KV)
|
5001-8000
|
8001-15000
|
15001-25000
|
25001-28000
|
28001-35000
|
35001-46000
| |
1 core, 3 core
| |||||||
Cross-section
mm2
|
1C
|
6AWG~1600kcmil
|
2AWG~1600kcmil
|
1AWG~1600kcmil
|
2AWG~1600kcmil
|
1/0AWG~1600kcmil
| |
3C
|
6AWG~1600kcmil
|
2AWG~1600kcmil
|
1AWG~1600kcmil
|
2AWG~1600kcmil
|
4/0AWG~1600kcmil
| ||