11kv 3 core 95mm2 CU/PVC/SWA/PVC power cable

11kv 3 core 95mm2 CU/PVC/SWA/PVC power cable

Applications of Medium Voltage Cable 

Used for power transmission and distribution line with voltage rated at 35kV and below.
Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.

Standards of Medium Voltage Cable 

International: IEC 60502-2, IEC 60228
China: GB/T 12706.2-2008
Other standards such as BS,DIN and ICEA upon request

Rated Voltage:6/10kV, 6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV
Core Number:Single Core or Three Core (1C or 3C)
Available Dimensions:25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2.
Codes Available:N2XSY, N2XSEY, NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY, N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY
YJV, YJLV, YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32
Application:For power networks, underground, outdoors and in cable ducting. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected during installation.
Construction: 
Conductor:Stranded round compacted copper or aluminum conductor (Cu / Al ), copper wire annealed.
Conductor Screen:Semi-conducting material
Insulation:XLPE (Cross-Linked Polyethylene)
Insulation Screen:Semi-conducting material
Metallic Screen:Copper tape screen or copper wire screen (CTS / CWS )
Filler:PP rope
Separator:Binding tape
Bedding:PVC (Polyvinyl Chloride)
Armouring:Single Core: Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA)
Sheath:PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Colour:Red or Black
Temperature Rating:0°C to 90°C
Minimum Bending Radius:Single Core: 15 x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)


Rated voltage(KV)
3.6/6
6/6
6/10
8.7/10
8.7/15
12/15
12/20
18/20
18/30
21/35
26/35
Core Number
1 core, 3 core
Cross-section
mm2
1C
25~800
35~800
3C
25~400
35~400

b) IEC/BS/DIN standard
Rated voltage(KV)
3.6/6
6/6
6/10
8.7/10
8.7/15
12/15
12/20
18/20
18/30
21/35
26/35
Core Number
1 core, 3 core
Cross-section
mm2
1C
25~800
35~800
3C
25~400
35~400

  c) ASTM standard
Rated voltage(KV)
5001-8000
8001-15000
15001-25000
25001-28000
28001-35000
35001-46000
 
1 core, 3 core
Cross-section
mm2
1C
6AWG~1600kcmil
2AWG~1600kcmil
1AWG~1600kcmil
2AWG~1600kcmil
1/0AWG~1600kcmil

3C
6AWG~1600kcmil
2AWG~1600kcmil
1AWG~1600kcmil
2AWG~1600kcmil
4/0AWG~1600kcmil