Solid or stranded conductor thermocouple extension cable (type JX/ KX/ EX/ TX )

Thermonuclear Wire that is used in a thermocouple from the point of sensing to the point of cold junction compensation (cjc end) where the signal is measured. A thermocouple is a sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. Different thermocouple types (e. G. J, K, T, E, etc) use different mixtures of metals in the wire. At the cjc end, the millivolt value provided by the thermocouple represents the difference in temperature of the sensing end as compared to the cjc end (also called the reference end).


Solid or stranded conductor thermocouple extension cable (type JX/ KX/ EX/ TX )

thermocouple compensation cable
Grade:Extension Grade or Thermocuple Grade
temperature range, deg. c-50  to  +400
type of coductor:K, J, T, E, N, S, R, KX, JX, TX, EX, NX, SX, RX
number of conductors:1,2,3,4,6
Conductor typeStrand or Solid
material of insulation:fiberglass, telfon, PTFE, PVC, silicone,so on 
material of jacket: fiberglass, telfon, PTFE, PVC, silicone,so on 
shielding material: Stainless Steel Braid and  Tinned Copper wire braid 


Solid or stranded conductor thermocouple extension cable (type JX/ KX/ EX/ TX


TypeDescription
KX-GS-VVPrecise grade compensational wire for thermocouple of K type with PVC
 insulation and sheath for general purpose
KX-GS-VPVPrecise grade compensational wire for thermocouple of K type
with PVC insulation and sheath, copper wire braided shielding
 for general purpose
KX-HS-FFPrecise grade high temperature compensational wire for
 thermocouple of K type with Fluoroplastic insulation and
sheath for heat resistant purpose
KX-HS-FP1FPrecise grade high temperature compensational wire
for thermocouple of K type with Fluoroplastic insulation
and sheath, tinned copper wire braided shielding for
heat resistant purpose
KX-HS-FBPrecise grade high temperature compensational
 wire for thermocouple of K type with F4 insulation
and glass wire braided sheath for heat resistant purpose
KX-HS-FBP1Precise grade high temperature compensational wire
for thermocouple of K type with F46 wrapped insulation
glass wire braiding, tinned copper wire braided shielding
 and glass wire braided outer sheath for heat resistant purpose
KX-HS-FP1V105Precise grade high temperature compensational wire
 for thermocouple of K type with Fluoroplastic insulation,
tinned copper wire braided shielding, 105ºC heat resistant
 and PVC sheath for heat resistant purpose
KX-GS-VVPrecise grade compensational cable for thermocouple of
K type with PVC insulation and twinning PVC sheath for
general purpose
KX-GS-VPVPrecise grade compensational cable for thermocouple
of K type with PVC insulation, twinning copper wire braided
 individual shielding, PVC sheath for general purpose
KX-GS-VPVPPrecise grade compensational cable for thermocouple of
 K type with PVC insulation, twinning copper wire braided
 individual & general shielding, PVC sheath for general purpose
KX-GS-VVPPrecise grade compensational cable for thermocouple
of K type with PVC insulation, twinning copper wire braided
 general shielding, PVC sheath for general purpose
KX-HS-FFPrecise grade high temperature compensational cable
for thermocouple of K type with Fluoroplastic insulation
and twinning Fluoroplastic sheath
KX-HS-FP1FPrecise grade high temperature compensational cable
 for thermocouple of K type with Fluoroplastic insulation,
 twinning tinned copper wire braided individual shielding
and Fluoroplastic sheath
KX-HS-FP1FP1Precise grade high temperature compensational cable
 for thermocouple of K type with Fluoroplastic insulation,
twinning tinned copper wire braided individual & general
 shielding and Fluoroplastic sheath
KX-HS-FFP1Precise grade high temperature compensational cable
for thermocouple of K type with Fluoroplastic insulation,
 twinning tinned copper wire braided general shielding
and Fluoroplastic sheath
KX-HS-FV 105Precise grade high temperature compensational cable
 for thermocouple of K type with Fluoroplastic insulation,
twinning 105ºC heat resistant PVC sheath
KX-HS-FP1V105Precise grade high temperature compensational cable
 for thermocouple of K type with Fluoroplastic insulation,
twinning tinned copper wire braided individual shielding
105ºC heat resistant PVC sheath
KX-HS-FP1V105P1Precise grade high temperature compensational cable
 for thermocouple of K type with Fluoroplastic insulation,
twinning tinned copper wire braided individual and general
shielding 105ºC heat resistant PVC sheath
KX-HS-FV105  P1Precise grade high temperature compensational cable
 for thermocouple of K type with Fluoroplastic insulation,
twinning tinned copper wire braided general shielding
105ºC heat resistant PVC sheath
Thermocouple Extension Wire or Cable
Main Technical Requirement
TypeCompensational wire coreInsulation color of compensational wireThermocouple type
plusminusplusminus
SC or RCCu0.6 Cu-Niredgreen(PtRh10-PT) or   R (PtRh13-PT)
KCAFeCu-NiredblueK (NiCr-NiSi)
KCBCuCu-Niredblue
KXNi-Cr 10Ni-Siredblack
EXNi-Cr 10Cu-NiredbrownE (NiCr-NiSi)
JXFeCu-NiredvioletJ (Fe-CuNi)
TXCuCu-NiredwhiteT (Cu-CuNi)
NCFeCu-NiredgreyN (NiCrSi-NiSi)
NXNi-Cr 14 SiNi-Siredgrey




Comments

Popular posts from this blog

PVC/Round 3 and 4 Core Flat/Round Cables for pump

16mm2 Electrical Connecting Battery Cable Power Cable with Terminals

6 Gauge AWG Copper Battery Cable Terminal lug Tinned 5/16inch or 3/8inch